BRKKG - TX801,P/N: 22-00007-00,DISK DRIVE HEAD CLNR

  • MSDS: BRKKG
  • Manufacturer: K ELECTRONICS
  • Product Name: TX801,P/N: 22-00007-00,DISK DRIVE HEAD CLNR
  • National Stock Number: 7045-01-115-7444
Product Identification

Product ID:TX801,P/N: 22-00007-00,DISK DRIVE HEAD CLNR
MSDS Date:08/26/1986
FSC:7045
NIIN:01-115-7444
MSDS Number: BRKKG

Responsible Party
K ELECTRONICS
3987 DARDEN DR.
BEAVERCREEK,DAYTON, OH 45421-2399
US

Emergency Phone: 513-426-1877

Info Phone: 513-426-1877

Preparer: DGSC-SSH

Cage: 4H100

Contractor
TEXWIPE COMPANY
UPPER SADDLE RIVER, OH 45421-2399 US

Telephone: 201-327-9100

Cage: 21944

Ingredients

ISOPROPYL ALCOHOL (SARA III)

CAS: 67-63-0

RTECS: NT8050000

Fraction By Weight: 91.0%

OSHA PEL 400 PPM/500 STEL

ACGIH TLV: 400 PPM/500STEL;9192

Hazards

LD50 LC50 Mixture:TLV ISOPROPYL ALCOHOL=400PPM
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:INHAL:UPPER RESPIRATORY TRACT
IRRITATION.HIGH CONCENTRATIONS CAN CAUSE
DROWSINESS,ATAXIA,NARCOSIS.SKIN:BRIEF EXPOSURE
NON-IRRITATING.EYES:MILD TO SEVERELY IRRITATING.INGEST:LD HUMAN=131
G;IRRITATES GI TRACT.
Effects of
Overexposure:SKIN:CRACKING,DRYNESS.INGEST:DROWSINESS,CRAMPS,NAUSEA,
VOMITING,DIARRHEA ...UNCONSCIOUSNESS,DEATH.
Medical Cond Aggravated by Exposure:NO DATA.

First Aid

First Aid:SKIN: REMOVE CONTAMINATED CLOTHING.WASH WITH SOAP AND
WATER.CALL A PHYSICIAN IF IRRITATION PERSISTS. INHALATION: REMOVE
TO FRESH AIR & RESTORE BREATHING IF NECESSARY.CALL A PHYSICIAN.
EYES: IMMEDIATEL Y FLUSH WITH WATER FOR 15 MINUTES WHILEHOLDING
EYELIDS OPEN.GET MEDICAL HELP. INGESTION: IMMEDIATELY CALL A
PHYSICIAN.DO NOT INDUCE VOMITING.GIVE WATER IF CONSCIOUS. NOTHING
BY MOUTH IF UNCONSCIOUS.

Fire Fighting

Flash Point Method:CC
Flash Point:53.6F,12.0C
Lower Limits:2.5
Upper Limits:12
Extinguishing Media:CARBON DIOXIDE, ALCOHOL FOAM, DRY CHEM.
Fire Fighting Procedures:USE WATER AS FOG, STREAM MAY NOT BE EFFECTIVE,
COOL CONTAINERS, AVOID BREATHING TOXIC VAPORS;USE A SELF-CONTAINED
BREATHING APPARATUS.
Unusual Fire/Explosion Hazard:NONE

Accidental Release

Spill Release Procedures:WEAR PROTECTIVE CLOTHING. REMOVE ALL IGNITION
SOURCES. VENTILATE AREA OF SPILL. USE WATER SPRAY TO REDUCE VAPORS,
ABSORB ON TOWELS. EVAPORATE SMALL QUANTITIES IN SAFE AREA. DO NOT
ALLOW TO ENTER CONFI NED AREA OR SEWER.
Neutralizing Agent:NONE

Handling

Handling and Storage Precautions:STORE IN COOL, DRY WELL VENTILATED LOW
FIRE RISK AREA. PROTECT FROM HEAT. KEEP CONTAINERS CLOSED.
Other Precautions:NONE

Exposure Controls

Respiratory Protection:WHERE ENVIRONMENTAL CONTROLS ARE LACKING OR IN
ENCLOSED SPACES USE A SELF-CONTAINED BREATHING APPARATUS.
Ventilation:MECHANICAL (GENERAL) ROOM VENTILATION IS NORMALLY ADEQUATE.
Protective Gloves:NOT NESCESSARY
Eye Protection:NOT NEEDED
Other Protective Equipment:NONE
Work Hygienic Practices:PRACTICE GENERAL INDUSTRIAL HYGEIN
PRACTICE.KEEP AREA CLEAN.WASH THOROGHLY AFTER EACH USE OR
HANDLING.AVOID CONTACT.
Supplemental Safety and Health
CLEANING KIT CONSISTS OF 9 TEXPADS IN INDIVIDAL PACKETS SATURATED WITH
ISOPROPANOL.DGSC-SSH HAS PREPARED THIS RECORD FROM CCINFO-MSDS
DATBASE FOR ISOPROPANOL.

Chemical Properties

HCC:F2
NRC/State Lic Num:NONE
Boiling Pt:=82.8C, 181.F
Vapor Pres:33 MMHG
Vapor Density:2.1
Spec Gravity:0.78
Evaporation Rate & Reference:2.83 BUAC=1
Solubility in Water:MISCIBLE
Appearance and Odor:COLORLESS LIQUID WITH SLIGHT ODOR
Percent Volatiles by Volume:100

Stability

Stability Indicator/Materials to Avoid:YES
STRONG OXIDIZERS.
Stability Condition to Avoid:HEAT,FLAME,FIRE,OR OTHER IGNITION SOURCES.
Hazardous Decomposition Products:INCOMPLETE COMBUSTION WILL PRODUCE
OXIDES OF CARBON.

Disposal

Waste Disposal Methods:DISPOSE OF IN ACCORDANCE WITH FEDERAL,STATE AND
LOCAL REGULATIONS.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.